GreenShield Gaskets

Greenshield GasketsWith the need to further minimize the ecological impact of the Electronic Industry and to pro-actively prepare for the forthcoming new environmental policies, Schlegel Electronic Materials (SEM) set the tone and introduces today GREENSHIELD, a complete halogen free EMI gaskets program. SEM R&D team developed a new foam and flame retardant resin which combined with SEM's highly conductive fabrics, confer to GREENSHIELD's EMI gaskets V0 rating (UL94 specification-Underwriters Laboratories Inc.) and Halogen Free label as defined In IEC 61249-2-21 standard. Despite the high reactivity of these chemical elements, the consistency of levels of halogens is insured through specific on-line quality inspection.

 

Greenshield GasketsGREENSHIELD also features low compression set and excellent compression load/dedflection characteristics. GREENSHIELD is available with current Schlegel Electronic Materials manufacturing program including the unique continuous forming process so that our Customers can design today products in full compliance with tomorrow's regulations and limited impact on the environment. GREENSHIELD is in full compliance with European Union Directives 2015/863/EU (RoHS 2.0) and 2002/96/EC (WEEE).

 

 

 

 

TECHNICAL SPECIFICATIONS

CHARACTERISTIC SPECIFICATION TEST METHOD
Shielding effectiveness

96 dB average : NiCu-C70

97.4 dB average: NiCu-C12

MIL DTL 83528 C
Surface Resistance

<=0.066 Ohms/sq. : NiCu-C70

<= 0.024 Ohms/sq. : NiCu-C12

ASTM F390
Contact Resistance at 1kg load

<0.11 0hm/inch :NiCu-C70

<0.08 Ohm/inch :NiCu-C12

SEM LP-3001
Operating Temperature -40°C , +70°C ASTM D3574
Abrasion resistance >= 800,000 cycles ASTM D3886
Flammability UL 94 V0 UL Standard
Compliance RoHS and WEEE Compliance 2015/863/EU (RoHS 2.0)
2002/96/EC (WEEE)
Halogen Content

<=900 ppm chlorine &

<=900 ppm bromine &

1500 ppm max for both

IEC 61249-2-21 / EN 14852 B

The technical specification data is based on SEM tesrts and analysis that we believe to be reliable.
However, in no event, shall SEM be liable for inaccuracies or omissions contained therein. In all cases, details and values should be verified by the customer liable for inaccuracies or omissions contained therein. In all cases, details and values should be verified by the customer
-UL is a registered trademark of Underwriters Laboratories, Inc.

 

Part Number Guide:
EXX8NMXXXXXHF

EXX: SEM Profile
N: 3:NiCu-C70 Ripstop Fabric
4:NiCu-C12 Plain Weave Fabric
8: Halogen Free & Flame Retardant PU Foam
M: Finishing/Attachment system (refer to SEM Profile Selection Guide)
XXXXX: Length in the form XXX.XX
Please consult Schlegel Electronic Materials Representatives to confirm availability of products